Changes for page Field Metadata
Last modified by robert on 2024/05/17 16:51
Summary
-
Attachments (0 modified, 0 added, 1 removed)
Details
- example_metadata.txt
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.robert - Size
-
... ... @@ -1,1 +1,0 @@ 1 -2.6 KB - Content
-
... ... @@ -1,46 +1,0 @@ 1 -# AKL-HR Node Array (AHNA) code X5 2 -CITE: Name, Name, and Name. (2023). A Node Array [Data set]. International Federation of Digital Seismograph Networks. https://doi.org/10.7914/8jxr-7029 3 - 4 -#SITE START END LAT LONG ELEV SPS RECORDER S/N SENSOR S/N PROPERTY,LOCALITY,COUNTRY COMMENTS 5 - 6 -# INSTALL 7 -AKL01 20-05-2023T00:00 30-06-2023T00:00 -37.0471 175.5245 75 250 SSNODE_C 590001950 SSNODE_5S 590001950 "Te Puru,Hauraki,NZ" 8 -AKL02 20-05-2023T00:00 30-06-2023T00:00 -36.7476 175.5026 70 250 SSNODE_C 590001943 SSNODE_5S 590001943 "Coromandel Town,Hauraki,NZ" 9 -AKL03 20-05-2023T00:00 30-06-2023T00:00 -36.9694 175.5020 98 250 SSNODE_C 590002068 SSNODE_5S 590002068 "Te Mata,Hauraki,NZ" 10 -AKL05 19-05-2023T19:00 22-02-2023T00:00 -36.5996 174.3312 102 250 SSNODE_C 590001957 SSNODE_5S 590001957 "South Head South,Auckland,NZ" "site was disturbed" 11 -AKL06 19-05-2023T19:00 30-06-2023T00:00 -37.2459 175.3426 34 250 SSNODE_C 590001930 SSNODE_5S 590001930 "Back Miranda,Auckland,NZ" 12 -AKB05 02-05-2023T00:37 30-06-2023T00:00 -36.6651 175.4800 63 250 TSAWR TS085A TRILL120 4875 "Colville,Hauraki,NZ" 13 - 14 -# SERVICE 1 15 -AKL05 22-02-2023T00:00 30-06-2023T00:00 -36.5996 174.3312 102 250 SSNODE_C 590001999 SSNODE_.2S 590001999 "South Head South,Auckland,NZ" "swapped node to shortperiod" 16 - 17 - 18 - 19 - 20 -################### ANY LINE BEGINNING WITH # will be commented! Comments are good! 21 - 22 - 23 -# NOTES 24 -# the start/end time is not critical, but good to have. what IS critical are the times of instrument changes as this potentially affects response information 25 -# to mark equipment changes, add a new line with an updated start date (e.g. AKL05 above) 26 -# can use tabs or spaces, but spaces tend to look nicer. formatting ultimately doesn't matter too much so long as there are spaces between the fields 27 -# if you don't know a serial number, put 999. if you don't know the elevation, put 0 28 -# for Nodes, put the same serial number for both Recoder and Sensor (since they are the same!) 29 - 30 - 31 -# EXAMPLE INSTRUMENT LABELS 32 -#LPR200 = ANU LPR-200 logger (beige box) 33 -#TSAWR = ANU TerraSAWR logger (yellow box) 34 - 35 -#TRILL120 = Trillium Compact 120s 36 -#TRILL20 = Trillium Compact 20s 37 -#TRILL120PH = Trillium Compact 120s PostHole 38 -#CMG6TD = Guralp 6TD 39 -#CMG3ESP = Guralp 3ESP 40 -#3DLITE = Lenarrtz 3D-LITE 41 - 42 -#SSNODE_C = output was in COUNTS (there is also SSNODE_MV, if you (accidentally!) output to millivolts etc) 43 -#SSNODE_5S = broadband (can also use SSNODE_BB) 44 -#SSNODE_.2S = shortperiod (can also use SSNODE_SP) 45 - 46 -#it doesn't matter too much what you use, so long as they are consistent and otherwise defined somewhere in the comments!