Changes for page AusPass Data
Last modified by robert on 2026/02/12 14:01
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -23,7 +23,7 @@ 23 23 24 24 (% class="box warningmessage" %) 25 25 ((( 26 - NOTEAusPass no longer hosts AU networkmetadata~-~- you will have to get this from Earthscope/IRIS.26 +Unfortunately, AusPass no longer hosts AU network data~-~- you will now have to get this from Earthscope/IRIS. 27 27 ))) 28 28 29 29 == QA/QC == ... ... @@ -46,14 +46,26 @@ 46 46 47 47 Soon we will also begin hosting regionally specific catalogs with full phase picks. 48 48 49 -= SmartSolo Node ZPolaritybug=49 += SmartSolo Node Polarity Issues = 50 50 51 - In late2023 it was discoveredthatthevertical Z channelof **all**SmartSolonodes is actuallyinverted relative tothe standard expectationof"positiveup" (vertical axisdip = -90). EarthScope's solutionwas toadd a -1 multiplierto the//response data.//Because we have a much smaller volume of thisdatatofix,andfarless of it already distributed prior to thisannouncement,we have opted to do the opposite;e.g.weinvert the //raw data// becausethe datais what is wrong;nottheresponse.51 +There has been a lot of confusion about the polarity of the IGU-16HR (1C and 3C) data, as well as the BD3C-5 data over the years. 52 52 53 -As such, 53 +(% class="box errormessage" %) 54 +((( 55 +ALL IGU-16HR channels have **negative** polarity relative to "standard" FDSNXML convention (e.g., positive down = -90 degrees, positive north = 0 degrees, positive east = 90 degrees). Freshly exported data requires a -1 multiplier relative to be "correct" relative to what you're likely expecting. 56 +))) 54 54 55 -{{warning}} 56 -Do not mix up EarthScope's or the IRIS-NRL node response data with those available at AusPass. Theirs will likely be inverted relative to our data! 57 -{{/warning}} 58 +(% class="box infomessage" %) 59 +((( 60 +BD3C-5 channels are "normal" and consistent with usual high gain seismometers. These sensors do not require any polarity flips. 61 +))) 58 58 63 +After much consternation was have finally tested this ourselves in a controlled environment, and have also consulted various agencies. We are now certain the above notices to be correct. Other researchers have demonstrated the same, e.g. the below. 64 + 65 +[[Arrivals showing the polarity of various instrument types (courtesy of the China Earthquake Administration). Note that the IGU-16HR3C (labelled HR3C) are inverted relative to the BD3C and CMG40T. >>image:Weixin Image_20260115150150_19_1185.png||alt="Arrivals showing various sensors. The HR3C channels are inverted."]] 66 + 67 +As of December 2025, all data on AusPass is now correct. Previously it was understood that only the "Z" channel data on the IGU-16HRs was incorrect. It is unclear how other agencies handle this, but for that reason we do not advise mixing up response information from what is provided on AusPass. It is possible that other groups account for this by adding a multiplier in the metadata and not by editing the waveform data. 68 + 59 59 70 + 71 +
- Weixin Image_20260115150150_19_1185.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.robert - Size
-
... ... @@ -1,0 +1,1 @@ 1 +629.1 KB - Content