Changes for page Freight & Cleaning

Last modified by robert on 2025/12/22 13:51

From version 49.1
edited by KB
on 2025/12/16 17:56
Change comment: There is no comment for this version
To version 33.1
edited by Jack Dent
on 2025/01/02 11:13
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Freight & Cleaning
1 +Seismometers
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Kimberley
1 +XWiki.JackD
Content
... ... @@ -2,56 +2,64 @@
2 2  (((
3 3  (% class="col-xs-12 col-sm-8" %)
4 4  (((
5 -== Freight ==
5 += Broadband sensors =
6 6  
7 -We usually pack equipment on pallets, in transporter cases, or in boxes. This depends on a range of factors, including:
7 +Broadband (or BB) sensors are especially sensitive to low-frequency energy and are //broad//ly defined as any instrument capable of **reliably recording wave periods greater or equal to 10 seconds**. This makes them useful for the analysis and detection of teleseismic earthquakes as well as techniques involving ambient noise. However, they are also well-suited for measuring high-frequency energy, limited only by the Nyquist frequency of the [[data logger>>doc:Instrumentation.ANU LPR-200.WebHome]]'s sampling rate. The downside to broadband sensors is usually their cost, size, and fragility relative to short-period sensors.
8 8  
9 -* staff and facilities available at your institute
10 -* shipping method (air, sea, road/rail)
11 -* access for inspectors en route (e.g., customs or dangerous goods).
9 +== Nanometrics ==
12 12  
13 -In most instances, we provide dimensions for the borrower to quote and book freight directly with their preferred carrier. This simplifies billing and insurance arrangements. However, we will still assist with technical details throughout your booking if needed.
11 +Currently, 4 kinds of nanometric broadband seismic sensors are available. The Trillium Compact 120, Trillium Compact 20, Trillium Compact Posthole, and most recently, the Trillium Compact Horizon. These seismometers are ideal for long-term deployments of multiple months. All of these seismometers are compatible with the LPR-200 and TSAWR loggers and are designed for low energy consumption.
14 14  
15 -Directions for return freight will be provided with your Supply Agreement.
13 +=== Trillium Compact 120 ===
16 16  
17 -----
15 +The Trillium Compact 120 has a recording range between 120 seconds and 100Hz.
18 18  
19 -== Arrive clean, leave clean ==
17 +What info?
20 20  
21 -Plan ahead to ensure your teams have the time and tools they need to avoid moving organic material between sites and regions. Factors to consider include site conditions, vehicle capacity, water and laundry access.
19 +- Recording frequency range?
22 22  
23 -At minimum, we ask users to follow the basic checklists below for sites in __low-risk__ biosecurity areas. If you are working in higher-risk areas, please discuss your field hygiene plan with us as early as possible, so we can coordinate pre and post-treatments.
21 +- Sensitivity?
24 24  
25 -**Before install: **We will do our best to supply clean instruments, but please do a quick final check for seeds and stowaways before burial.
23 +- Adjustable feet and levelling bubble?
26 26  
27 -**Before leaving the site:**
25 +For more information, refer to the Nanometrics instrument information sheet: [[https:~~/~~/nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]]
28 28  
29 -1. Brush off as much dirt as possible.
30 -1. Inspect crevices for insects, eggs, seeds, etc.
31 -1. Wipe instruments clean if placing directly into foam or textile cases.
27 +=== Trillium Compact 20 ===
32 32  
33 -**Before packing equipment for return:**
29 +The Trillium compact has a recording range between 20 seconds and 100Hz. These instruments also have a tilt tolerance of 10° making for efficient deployment.
34 34  
35 -1. Check again for insects and loose debris.
36 -1. Check that data cards are removed (and safely stored).
37 -1. Wipe surfaces clean with diluted castile or other mild soap (keeping connectors and electronics dry).
38 -1. Let everything dry well before packing.
31 +For more information, refer to the Nanometrics instrument information sheet: [[https:~~/~~/nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact.pdf?hsLang=en-ca]]
39 39  
40 -Note: Our technicians will clean connectors and tougher stains in the lab.
33 +(% style="color:inherit; font-family:inherit; font-size:max(18px, min(20px, 14.4444px + 0.462963vw))" %)Trillium Compact Posthole
41 41  
42 -If your field hygiene plan requires treatments stronger than regular soap or warm water, please discuss with us first.
35 +The Trillium Compact Posthole is designed with a robust casing allowing it to be deployed without a vault or protective case.
43 43  
44 -**Can we pay ANU Earth Imaging to do it for us?**
37 +For more information, refer to the Nanometrics instrument information sheet [[https:~~/~~/nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact_ph.pdf?hsLang=en-ca>>https://nanometrics.ca/hubfs/Downloads/Data%20Sheets/trillium_compact_ph.pdf?hsLang=en-ca]]
45 45  
46 -No, sorry. We recommend 'cleaning as you go' to minimise movement of organic material, and this includes movement back to our territory and campus. We understand this wasn't always considered necessary, and appreciate how quickly and willingly the community has adapted to this change.
39 +=== Trillium Compact Horizon ===
47 47  
48 -Your efforts also directly improve our research and support capacity, as dirty returns complicate operations in our lab and workshop.
41 +=== SmartSolo Broadbands ===
49 49  
50 -**How clean is clean enough?**
43 +Two types of SmartSolo brand seismometers are currently available, one of which is a broadband seismometer. More information is available on the SmartSolo Seismometers page.
51 51  
52 -We will post some example photos soon from our 2025/2026 summer backlog, indicating the standards considered reasonable for low-risk returns.
45 += Short period sensors =
53 53  
54 -There will often be a few missed spots, which is why we do a second check before testing, and a third check before packing for the next experiment.
47 +Short-period (SP) sensors have limited sensitivity to longer periods, but are otherwise perfectly suitable for earthquake or other high-frequency analysis. They are generally defined as any instrument that begins to **lose sensitivity at periods larger than 10 seconds**. They tend to be smaller and more mechanically robust to broadband sensors.
48 +
49 +=== Lennartz Electronic LE-3D Lite (MkII) ===
50 +
51 +etc
52 +
53 +=== SmartSolo Short periods ===
54 +
55 +Two types of SmartSolo brand seismometers are currently available, one of which is a short-period seismometer. More information is available on the SmartSolo Seismometers page.
56 +
57 +etc
58 +
59 +
60 +== Channel and Instrument conventions ==
61 +
62 +We follow FDSN guidelines for sensor channel and type naming conventions, outlined at [[SAGE / IRIS>>https://ds.iris.edu/ds/nodes/dmc/data/formats/seed-channel-naming/]]
55 55  )))
56 56  
57 57  (% class="col-xs-12 col-sm-4" %)
... ... @@ -62,11 +62,42 @@
62 62  
63 63  (% class="box" %)
64 64  (((
65 -== ==
73 += Trillium Compact 120 =
66 66  
67 -
75 += [[image:Trillium compact120.jpg]] =
76 +
77 +|**Frequency Band**|120 seconds to 100 Hz
78 +|**Sensitivity**| 754 V/m/s
79 +|**Size (Diameter x Height)**|9 x 13 cm
80 +|**Weight**|1.1 kg
68 68  )))
69 69  
83 +(% class="box" %)
84 +(((
85 += Trillium Compact PostHole 120 =
86 +
87 += [[image:Trillium compact posthole.jpg]] =
88 +
89 +|**Frequency Band**|120 seconds to 100 Hz
90 +|**Sensitivity**| 754 V/m/s
91 +|**Size (Diameter x Height)**|10 x 17 cm
92 +|**Weight**|3.1 kg
93 +)))
94 +
95 +
96 +(% class="box" %)
97 +(((
98 += Lennartz LE-3D-Lite MkII =
99 +
100 += [[image:LE3Dlite.jpg||data-xwiki-image-style-alignment="~"center~""]] =
101 +
102 +
103 +|**Frequency Band**|1 seconds to 100 Hz
104 +|**Sensitivity**| 400 V/m/s
105 +|**Size (Diameter x Height)**|10 x 10 cm
106 +|**Weight**|1.9 kg
107 +)))
108 +
70 70  
71 71  )))
72 72  )))
20250305_100107.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.JackD
Size
... ... @@ -1,1 +1,0 @@
1 -633.7 KB
Content