Changes for page Freight & Cleaning
Last modified by robert on 2025/12/22 13:51
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 9 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - Seismometers1 +Freight & Cleaning - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. robert1 +XWiki.Kimberley - Content
-
... ... @@ -2,39 +2,56 @@ 2 2 ((( 3 3 (% class="col-xs-12 col-sm-8" %) 4 4 ((( 5 -= Broadband sensors=5 +== Freight == 6 6 7 - Broadband (or BB) sensorsare especiallysensitiveto low frequencyenergy,and are //broad//ly defined asanyinstrument capable of **reliably recording waveperiods greateror equal to 10seconds**.Howeverthey are also well-suitedfor measuringhighfrequency energy aswell, limitedonlybythe Nyquist frequencyofthe [[data logger>>doc:Instrumentation.Data Loggers.WebHome]]'ssamplingrate.7 +We usually pack equipment on pallets, in transporter cases, or in boxes. This depends on a range of factors, including: 8 8 9 -== Nanometrics Trillium == 9 +* staff and facilities available at your institute 10 +* shipping method (air, sea, road/rail) 11 +* access for inspectors en route (e.g., customs or dangerous goods). 10 10 11 -etc 13 +In most instances, we provide dimensions for the borrower to quote and book freight directly with their preferred carrier. This simplifies billing and insurance arrangements. However, we will still assist with technical details throughout your booking if needed. 12 12 13 - ==Sub-paragraph==15 +Directions for return freight will be provided with your Supply Agreement. 14 14 15 - etc17 +---- 16 16 17 -== =Sub-subparagraph===19 +== Arrive clean, leave clean == 18 18 19 -etc 21 +Plan ahead to ensure your teams have the time and tools they need to avoid moving organic material between sites and regions. Factors to consider include site conditions, vehicle capacity, water and laundry access. 20 20 23 +At minimum, we ask users to follow the basic checklists below for sites in __low-risk__ biosecurity areas. If you are working in higher-risk areas, please discuss your field hygiene plan with us as early as possible, so we can coordinate pre and post-treatments. 21 21 22 - =Short periodsensors=25 +**Before install: **We will do our best to supply clean instruments, but please do a quick final check for seeds and stowaways before burial. 23 23 24 - Short period (SP) sensors have limited sensitivity to longerperiods, butare otherwiseperfectlysuitablefor earthquake or other high frequency analysis. They are generally defined as any instrument that begins to**lose sensitivity at periods larger that 10 seconds**.27 +**Before leaving the site:** 25 25 26 -== Sub-paragraph == 29 +1. Brush off as much dirt as possible. 30 +1. Inspect crevices for insects, eggs, seeds, etc. 31 +1. Wipe instruments clean if placing directly into foam or textile cases. 27 27 28 -e tc33 +**Before packing equipment for return:** 29 29 30 -== Sub-paragraph == 35 +1. Check again for insects and loose debris. 36 +1. Check that data cards are removed (and safely stored). 37 +1. Wipe surfaces clean with diluted castile or other mild soap (keeping connectors and electronics dry). 38 +1. Let everything dry well before packing. 31 31 32 -etc 40 +Note: Our technicians will clean connectors and tougher stains in the lab. 33 33 42 +If your field hygiene plan requires treatments stronger than regular soap or warm water, please discuss with us first. 34 34 35 - ==ChannelandInstrumentconventions==44 +**Can we pay ANU Earth Imaging to do it for us?** 36 36 37 -We follow FDSN guidelines for sensor channel and type naming conventions, outlined at [[SAGE / IRIS>>https://ds.iris.edu/ds/nodes/dmc/data/formats/seed-channel-naming/]] 46 +No, sorry. We recommend 'cleaning as you go' to minimise movement of organic material, and this includes movement back to our territory and campus. We understand this wasn't always considered necessary, and appreciate how quickly and willingly the community has adapted to this change. 47 + 48 +Your efforts also directly improve our research and support capacity, as dirty returns complicate operations in our lab and workshop. 49 + 50 +**How clean is clean enough?** 51 + 52 +We will post some example photos soon from our 2025/2026 summer backlog, indicating the standards considered reasonable for low-risk returns. 53 + 54 +There will often be a few missed spots, which is why we do a second check before testing, and a third check before packing for the next experiment. 38 38 ))) 39 39 40 40 (% class="col-xs-12 col-sm-4" %) ... ... @@ -43,10 +43,13 @@ 43 43 {{toc/}} 44 44 {{/box}} 45 45 46 -[[image:Templates.Article.Template.WebHome@image1.jpg]] 47 -//Figure 1: Trillium Compact 120s// 63 +(% class="box" %) 64 +((( 65 +== == 48 48 49 -[[image:Templates.Article.Template.WebHome@image2.jpg]] 50 -//Figure 2: Lennartz 3D_lite MKII// 67 + 51 51 ))) 69 + 70 + 52 52 ))) 72 +)))
- 20250305_100107.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.JackD - Size
-
... ... @@ -1,0 +1,1 @@ 1 +633.7 KB - Content
- GURALP 3ESP.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.JackD - Size
-
... ... @@ -1,0 +1,1 @@ 1 +817.0 KB - Content
- Guralp 3ESPC.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.JackD - Size
-
... ... @@ -1,0 +1,1 @@ 1 +863.8 KB - Content
- Guralp 40T.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.JackD - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1007.9 KB - Content
- LE3Dlite.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.robert - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.5 KB - Content
- Screenshot 2023-12-12 at 12-28-47 Trillium Compact Nanometrics.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.robert - Size
-
... ... @@ -1,0 +1,1 @@ 1 +197.9 KB - Content
- Trillium compact 120.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.JackD - Size
-
... ... @@ -1,0 +1,1 @@ 1 +756.2 KB - Content
- Trillium compact posthole.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.JackD - Size
-
... ... @@ -1,0 +1,1 @@ 1 +854.8 KB - Content
- Trillium compact120.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.JackD - Size
-
... ... @@ -1,0 +1,1 @@ 1 +531.9 KB - Content